UrOops3D, danger-zone atlas
UP-016-c03 Benign outlet intraoperative
HoLEP and endoscopic enucleation of the prostate

Bladder injury during morcellation

Poor visibility, loss of distension or tissue adherence to the wall can allow the morcellator to injure bladder mucosa or perforate the bladder.

This module records catalogue coverage only. Do not use it to make diagnosis or treatment decisions.

Rendered frame from the Interactive operative model Interactive 3D The operation this complication belongs to: HoLEP and endoscopic enucleation of the prostate Interactive operative model Open the 3D animation

Which versions of the operation this applies to

Holmium laser enucleationThulium laser enucleationBipolar endoscopic enucleationEn-bloc enucleationMulti-lobe enucleation

The parent hub contains 5 recorded variations.

The labels above prevent a complication from being implied for an approach where it is not relevant.

Compare all HoLEP / enucleation variations

Sources

Other HoLEP / enucleation complication modules

Return to the complete procedure hub